Structural Drawing for Punjab State Board of Technical Education Diploma in Engineering students in Civil Engineering, 6th semester, is listed here to help you find subject-wise previous year question papers and old papers for exam preparation. Students can use this page to review paper style, understand repeated question patterns, and revise important topics before the exam. BRpaper is not the official website of Punjab State Board of Technical Education. It only helps students discover structural drawing question paper material and related previous year papers for better revision and practice.
Solved Questions
Solved-
Draw to a suitable sectional plan and sectional elevation of simply supported one-way slab with the following data: Room size = 3m x 6m; thickness of slab = 150mm; bearing on walls = 150mm; wall thickness = 300mm; reinforcement: main bars = 12mm dia bars @150mm c/c with alternate bars bent-up at 0.45m from centre of bearing; distribution steel = 10mm dia bars @200mm c/c.Long Answer 25 Marks May-2020 • PSBTE DIPLOMA
-
May 2022 Draw sectional plan and sectional elevation of simply supported one-way slab with the following data: Size of room = 3.5 m x 7.5 m; Thickness of wall = 500 mm; Bearing on wall = 300 mm; Reinforcement detail of HYSD bars; Main bars = 12 mm dia. @ 150 mm c/c (with alternative bars bent up); Distribution steel = 10 mm dia. bars @ 200 mm c/c; Assume thickness of slab.
-
May 2022 Draw sectional plan and sectional elevation of simply supported one-way slab with the following data: Size of room = 3.5m x 7.5m; Thickness of wall = 500mm; Bearing on wall = 300mm; Reinforcement detail of HYSD bars; Main bars = 12mm dia. @ 150 mm c/c (with alternative bars bent up); Distribution steel = 10mm dia. bars @ 200mm c/c. Note: Assume thickness of slab.
-
May 2021 Draw sectional plan and sectional elevation of a simply supported one way slab with the given data: room size 3.5 m × 7.5 m, bearing on wall 300 mm, slab thickness 150 mm, wall thickness 500 mm, HYSD reinforcement details with main bars 12 mm dia @ 150 mm c/c (alternate bars bent up) and distribution steel 10 mm dia @ 200 mm c/c. Prepare bar bending schedule.
-
May 2019 Draw sectional plan and sectional elevation of a simply supported one-way slab with the given data: room size 4 m x 7.5 m, wall thickness 500 mm, bearing on wall 300 mm, slab thickness 150 mm, HYSD reinforcement details: main bars 12 mm dia @ 150 mm c/c with alternative bars bent up, and distribution steel 10 mm dia bars @ 200 mm c/c.
-
May 2018 Draw to a suitable sectional plan and sectional elevation of simply supported one-way slab with the following data: Room size = 3 m x 6 m; Thickness of slab = 150 mm; Bearing on walls = 150 mm; Wall thickness = 300 mm; Reinforcement: Main bars = 12 mm dia bars @ 150 mm c/c with alternate bars bent-up at 0.45 m from centre of bearing; Distribution steel = 10 mm dia bars @ 200 mm c/c.
-
Dec 2017 Draw sectional plan and sectional elevation of simply supported one-way slab with the following data: Size of room = 3.5m x 7.5m; Thickness of wall = 500mm; Bearing on wall = 300mm; Thickness of slab = 150mm; Reinforcement detail of HYSD bars. Main bars = 12mm dia @ 150mm c/c (with alternative bars bent up); Distribution steel = 10mm dia bars @ 200mm c/c.
-
May 2016 Draw sectional plan and sectional elevation of a simply supported one-way slab with room size 3 m x 7 m, thickness of wall 500 mm, bearing on wall 300 mm, thickness of slab 150 mm, main bars 10 mm diameter @ 150 mm c/c with alternative bars bent up, and distribution steel 8 mm diameter bars @ 200 mm c/c.
-
May 2015 Draw sectional elevation of simply supported one-way slab with following data: Size of the room = 3 m x 7 m; Thickness of the wall = 500 mm; Bearing on the wall = 300 mm; Thickness of the slab = 150 mm; Main steel = 10 mm dia @ 150 mm c/c (with alternative bars bent-up); Distribution steel = 8 mm dia bars @ 200 mm c/c. Also prepare the Bar Bending Schedule.
-
May 2015 Draw sectional elevation of simply supported one-way slab with following data: Size of the room = 3 m x 7 m; Thickness of the wall = 500 mm; Bearing on the wall = 300 mm; Thickness of the slab = 150 mm; Main steel = 10 mm φ @ 150 mm c/c (with alternative bars bent-up); Distribution steel = 8 mm φ bars @ 200 mm c/c. Also prepare the Bar Bending Schedule.
-
Dec 2015 Draw sectional plan and sectional elevation of a simply supported one-way slab with the following data: room size 3 × 7 m; wall thickness 500 mm; bearing on wall 300 mm; slab thickness 150 mm; main bars 100 mm diameter @ 150 mm c/c (with alternate bars bent up); distribution steel 8 mm diameter bars @ 20 mm c/c.
-
Dec 2015 Draw sectional plan and sectional elevation of simply supported one-way slab with the following data: Size of room = 3 × 7m; Thickness of wall = 500mm; Bearing on wall = 300mm; Thickness of slab = 150mm; Main bars = 100mm Φ @ 150mm c/c (with alternative bars bent up); Distribution steel = 8mm Φ bars @ 20mm c/c.
-
-
Draw to a suitable scale cross-section of end connection of an Rcc column with Rcc beam from the given data: End column size = 400mm x 400mm; main bars = 8-16mm dia.; lateral ties = 8mm dia. @200mm c/c (double ties); beam size = 250mm x 400mm (including 100mm thick slab); main bars = 5-20mm dia., out of these two bars are bent up at l/7; stirrups = 8mm dia 2-legged stirrups @200mm c/c; anchor bars = 2-10mm dia.Long Answer 25 Marks May-2020 • PSBTE DIPLOMA
-
May 2019 Draw to a suitable scale the cross-section of a head connection of two beams on both sides of a column as per the given data: column size 500 mm x 500 mm, main bars 8-16 mm dia, lateral ties 8 mm dia @ 250 mm c/c (double ties), beam size 300 mm x 450 mm (including 100 mm thick slab), main bars 5-16 mm dia, with 2 bars bent up at L/7 from centre of column, stirrups 5-16 mm dia 2-legged @ 250 mm c/c, and anchor bars 2-13 mm dia. Also show a plan of the column.
-
Dec 2017 Draw to a suitable scale cross-section of an end connection of a column with a beam from the following data: End column: size = 400mm x 400mm; Main bars = 8-16mm dia bars; Lateral ties = 8mm dia @ 200mm c/c (double ties); Beam size = 200mm x 400mm (including 120mm thick slab); Main bars = 5-20mm dia (2 bars bent-up at l/7); Stirrups = 8mm dia 2-legged stirrups @ 220mm c/c; Anchor bars = 2-12mm dia.
-
Dec 2016 Draw to a suitable scale cross-section of end connection of an RCC column with RCC beam from data given below: end column size = 400 mm x 400 mm; main bars = 8-16 mm dia; lateral ties = 8 mm dia @ 200 mm c/c (double ties); beam size = 250 mm x 400 mm (including 100 mm thick slab); main bars = 5-20 mm dia, out of these two bars are bent up at l/7; stirrups = 8 mm dia 2-legged stirrups @ 200 mm c/c; anchor bars = 2-10 mm dia.
-
Dec 2015 Draw to a suitable scale the cross section of an end connection of two beams on both sides of a column as per the given data: column size 450 mm × 450 mm; main bars 8-16 mm diameter bars; lateral ties 8 mm diameter @ 250 mm c/c (double ties); beams size 300 mm × 450 mm (including 100 mm thick slab); main bars 5-16 mm diameter (2 bars bent up at l/7 from centre of column); stirrups 8 mm diameter, 2-legged @ 250 mm c/c; anchor bars 2-12 mm diameter. Also show the cross section of the column.
-
Dec 2015 Draw to a suitable scale cross section of an end connection of two beams on both sides of column as per data given below: Columns: Size = 450mm × 450mm; Main bar = 8-16 Φ bars; Lateral ties = 8mm Φ @ 250mm c/c (double ties); Beams: Size = 300mm × 450mm (including 100 mm thick slab); Main bars = 5-16 mm Φ (2 bars are bent up at l/7 from centre of column); Stirrups = 8mm Φ 2 legged @ 250mm cc; Anchor bars = 2-12 mm Φ. Also show the cross section of the column.
-
-
Draw to a suitable scale the sectional plan and sectional elevation of a circular column from the following details: diameter of circular column = 500mm; depth below G.L. = 1.0m; plinth level = 400mm above G.L.; height of ceiling above plinth level = 3.8m; reinforcement details: column main longitudinal steel = 6-20mm dia; lateral ties = 8mm dia @300mm c/c; footing size = 3m x 3m; thickness of footing = 300mm; reinforcement in footing = 12mm dia @290mm c/c both ways; assume the main bars of the columns are going into 150mm thick slabs. All reinforcement used is of HYSD Fe415 grade of steel. Also prepare bar bending schedule.Long Answer 25 Marks May-2020 • PSBTE DIPLOMA
-
May 2022 Draw to a suitable scale the sectional plan and sectional elevation of a circular column from the following details: Diameter of circular column = 500 mm; Depth below G.L. = 1.0 m; Plinth level = 400 mm above G.L.; Height of ceiling above plinth level = 3.8 m; Reinforcement details: column main longitudinal steel = 6-20 mm dia.; Lateral ties = 8 mm dia. @ 300 mm c/c; Footing size = 3.0 m x 3.0 m; Thickness of footing = 300 mm; Reinforcement = 12 mm dia. @ 290 mm c/c both ways. Assume that main bars of the columns are going into 150 mm thick slabs. All reinforcement used is of HYSD Fe 415 grade of steel. Also prepare the bar bending schedule.
-
May 2022 Draw to a suitable scale the sectional plan and sectional elevation of a circular column from the following details: Diameter of circular column = 500 mm; Depth below G.L. = 1.0 m; Plinth level = 400 mm above G.L.; Height of ceiling above plinth level = 3.8 m; Reinforcement details: column main longitudinal steel = 6-20 mm dia.; Lateral ties = 8mm dia. @ 300mm c/c; Footing size = 3.0 m x 3.0 m; Thickness of footing = 300 mm; Reinforcement = 12 mm dia. @ 290 mm c/c both ways. Assume that main bars of the columns are going into 150 mm thick slabs. All reinforcement used is of HYSD Fe 415 grade of steel. Also prepare the bar bending schedule.
-
May 2021 Draw sectional plan and sectional elevation of a square column with an isolated footing of uniform thickness from the given data: column size 450 mm × 450 mm, depth below G.L. 1.2 m, plinth level 300 mm above G.L., ceiling height above plinth level 3.5 m, column reinforcement 4–25 mm dia main bars and 8 mm dia lateral ties @ 300 mm c/c, footing size 2.2 m × 2.2 m, footing thickness 300 mm, footing reinforcement 12 mm dia bars @ 150 mm c/c both ways, and the main bars of the column are tied with the steel of 130 mm thick RCC slab. Prepare bar bending schedule.
-
May 2019 Draw the sectional plan and sectional elevation of a square column with an isolated footing of uniform thickness from the given data: column size 500 mm x 500 mm, depth below G.L. 1.2 m, plinth level 300 mm above G.L., height of ceiling above plinth level 3.5 m, column reinforcement 4-25 mm dia main bars and 8 mm dia lateral ties @ 300 mm c/c, footing size 2.5 m x 2.5 m, footing thickness 300 mm, reinforcement 12 mm dia bars @ 150 mm c/c both ways, and the main bars of the column are tied with the steel of 130 mm thick RCC slab. Assume any other missing data and prepare the bar bending schedule.
-
May 2018 Draw the sectional plan and elevation of a 450 x 450 mm square column from the following data: Longitudinal bars = 6 Nos. 20 mm dia; Transverse ties = 8 mm dia @ 300 mm c/c; Base reinforcement = 12 mm dia bars @ 150 mm c/c both ways; Footing = 1.2 m x 1.2 m; Thickness of footing at free end = 150 mm; Thickness of footing at column face = 250 mm; Concrete cover = 25 mm; Depth below G.L. = 1.2 m.
-
Dec 2018 Draw to a suitable scale sectional elevation and footing plane of circular column of 600 mm diameter with the following data: depth of foundation below GL = 1200 mm, plinth height = 400 mm, height of column above plinth = 3500 mm, column reinforcement main = 6 bars of 25 mm diameter, lateral ties = 8 mm diameter @ 300 mm c/c, footing size at bottom = 3500 mm x 3500 mm, size at top = 600 mm x 600 mm, footing thickness at column face = 800 mm, thickness at free end = 400 mm, reinforcement = 12 mm diameter @ 200 mm c/c both ways.
-
Dec 2017 Draw to a suitable scale the sectional plan and sectional elevation of a circular column from the following details: Diameter of circular column = 500mm; Depth below G.L = 1.0m; Plinth level = 400mm above G.L.; Height of ceiling above plinth level = 3.8m; Reinforcement details of column main longitudinal steel = 6-20mm dia; Lateral ties = 8mm dia @ 300mm c/c; Footing size of footing = 3.0m x 3.0m; Thickness of footing = 300mm; Reinforcement = 12mm dia @ 290mm c/c both ways. Assume that main bars of the columns are going into 150mm thick slabs. All reinforcement used is of HYSD Fe 415 grade of steel. Also prepare the bar bending schedule.
-
May 2016 Draw sectional elevation and footing plan of a circular column with diameter of column 500 mm, longitudinal main bars 8 nos. 25 mm diameter, lateral ties 8 mm diameter @ 300 mm c/c, diameter of footing 3.0 m, thickness at free end 400 mm and at column face 800 mm, reinforcement 12 mm diameter @ 250 mm c/c both ways. Assume cover.
-
Dec 2016 Draw to a suitable scale sectional elevation and footing plan of circular column of 500 mm dia. with the following data: Depth of foundation below GL = 1200 mm; plinth height = 400 mm; height of column above plinth = 3500 mm; column reinforcements main = 6-25 mm dia; lateral ties = 8 mm dia @ 300 mm c/c; footing size at bottom = 3500 mm x 3500 mm; size at top = 600 mm x 600 mm; footing thickness at column face = 800 mm; thickness at free end = 400 mm; reinforcement = 12 mm dia @ 200 mm c/c both ways.
-
May 2015 Draw to a suitable scale sectional plan and sectional elevation of a square column with isolated footing from the following data: Size of the column = 500 mm x 500 mm; Longitudinal main bars = 8-20 mm dia (Fe 415 Grade); Lateral ties = 8 mm dia @ 300 mm centre to centre (Double ties); Base reinforcement = 12 mm dia @ 200 mm c/c both ways; Height of the column = 3.6 m; Size of the footing = 3.0 m x 3.0 m; Thickness of footing at column face = 700 mm; Thickness of footing at free end = 400 mm; Depth below G.L. = 1.2 m; Plinth level above G.L. = 350 mm. Also prepare the Bar Bending Schedule.
-
May 2015 Draw to a suitable scale sectional plan and sectional elevation of a square column with isolated footing from the following data: Size of the column = 500 mm x 500 mm; Longitudinal main bars = 8-20 mm φ (Fe 415 Grade); Lateral ties = 8 mm φ @ 300 mm centre to centre (Double ties); Base reinforcement = 12 mm φ @ 200 mm c/c both ways; Height of the column = 3.6 m; Size of the footing = 3.0 m x 3.0 m; Thickness of footing at column face = 700 mm; Thickness of footing at free end = 400 mm; Depth below G.L. = 1.2 m; Plinth level above G.L. = 350 mm. Also prepare the Bar Bending Schedule.
-
Dec 2015 Draw to a suitable scale the sectional plan and sectional elevation of a circular column from the following details: diameter of circular column 500 mm; depth above G.L. 1.0 m; plinth level above G.L. 400 mm; height of column 3.8 m; main longitudinal steel 6-20 mm diameter; lateral ties 8 mm diameter @ 300 mm c/c; footing size 3.0 × 3.0 m; thickness of footing 300 mm; reinforcement 12 mm diameter @ 290 mm c/c both ways. Assume that the main bars of column are going into 150 mm thick slabs. All reinforcement used is of HYSD Fe-415 grade steel. Also prepare the bending schedule.
-
Dec 2015 Draw to a suitable scale the sectional plan and sectional elevation of a circular column from the following details: Diameter of Circular Column = 500mm; Depth above G.L. = 1.0m; Plinth level of above G.L. = 400mm; Height of column = 3.8m. Column Reinforcement: Main longitudinal steel = 6-20mm Φ; Lateral ties = 8mm Φ @ 300mm c/c. Footing details: Size of footing = 3.0 × 3.0m; Thickness of footing = 300mm; Reinforcement = 12mm Φ @ 290mm c/c (both ways). Assume that the main bars of column are going into 150mm thick slabs. All reinforcement used is of HYSD Fe-415 grade of steel. Also prepare the bending schedule.
-
-
Draw side view of a framed connection of a beam with that a flange of a column with the following data: Column = ISHB 300 @ 576.8 N/m; Beam = ISLB 250 @ 273.7 N/m; Cleat angles 2 – ISA 90 x 90 x 8mm; use 22 mm diameter rivets both on web of the beam and flange of column.Long Answer 25 Marks May-2020 • PSBTE DIPLOMA
-
May 2022 Draw to a scale the front and side elevation of unstiffened seated beam to column connection using the following data: Column = ISHB 300 @ 576.8 N/m; Beam = ISMB 225 @ 306.1 N/m; Seat angle = ISA 100 mm x 75 mm x 12 mm; Top cleat angle = ISA 90 mm x 90 mm x 8 mm; Nominal diameter of rivet = 20 mm.
-
May 2022 Draw to a scale the front and side elevation of seated beam to beam connection using the following data: Main beam = ISMB 500 @ 852.5 N/m; Secondary beam = ISLB 300 @ 369.8 N/m; Seat angle = ISA 100 mm x 90 mm x 10 mm; Top cleat angle = ISA 90 mm x 90 mm x 10 mm; Nominal diameter of rivet = 20 mm.
-
May 2022 Draw to a scale the front and side elevation of unstiffened seated beam to column connection using the following data: Column = ISHB300 @ 576.8 N/m; Beam = ISMB 225 @ 306.1 N/m; Seat angle = ISA 100mm x 75mm x 12mm; Top cleat angle = ISA 90mm x 90mm x 8mm; Nominal diameter of rivet = 20mm.
-
May 2022 Draw to a scale the front and side elevation of seated beam to beam connection using the following data: Main beam = ISMB 500 @ 852.5 N/m; Secondary beam = ISLB 300 @ 369.8 N/m; Seat angle = ISA 100mm x 90mm x 10mm; Top cleat angle = ISA 90mm x 90mm x 10mm; Nominal diameter of rivet = 20mm.
-
May 2021 Draw the front and side elevation of a column and two beams seated connection when two beams are connected to both flanges of the column, using the following data: column ISHB 300 @ 576.8 N/m, beam 2–ISMB 225 @ 306.1 N/m, seat angles 2–ISA 100 × 75 × 8 mm, top cleat angles 2–ISA 90 × 90 × 8 mm, and rivet diameter 20 mm.
-
May 2019 Draw two views, front and side elevation, of a column and two beams seated connection from the following data: when two beams are connected to both the flanges of the column, column ISMB 300 @ 576.8 N/m, beam 2-ISMB 225 @ 306.1 N/m, seat angles 2-ISA 100 x 75 x 8 mm, top cleat angle 2-ISA 90 x 90 x 8 mm, and diameter of rivet 20 mm. For ISHB 300 @ 576.9 N/m used as column, width of flange b = 250 mm, thickness of flange tf = 10.6 mm, thickness of web tw = 7.6 mm. For ISMB 225 @ 306.1 N/m, width of flange b = 110 mm, thickness of flange tf = 1.8 mm, thickness of web tw = 6.5 mm, gauge distance g = 60.
-
May 2018 Draw to a scale the front and side elevation of seated beam to beam connection using the following data: Main beam = ISMB 500@ 852.5 N/m; Secondary beam = ISMB 250@ 365.9 N/m; Seat angle = ISA 100 mm x 90 mm x 10 mm; Top cleat angle = ISA 80 mm x 80 mm x 10 mm; Nominal diameter of rivet = 20 mm.
-
May 2016 Draw side view of a framed connection of a beam with the flange of a column with the following data: column ISHB 300 @ 576.8 N/m, beam ISLB 250 @ 273.7 N/m, cleat angles 2-ISA 90 x 90 x 8 mm, use 22 mm diameter rivets both on web of the beam and flange of column.
-
Dec 2016 Draw front and side elevation of seated beam to beam connection from the following data: main beam = ISMB 550 @ 1017.3 N/m; secondary beam = ISMB 250 @ 365.9 N/m; seat angle = ISA 100 mm x 90 mm x 10 mm; top cleat angle = ISA 80 mm x 80 mm x 10 mm; dia. of rivet = 20 mm.
-
May 2015 Draw to a suitable scale the front and side elevation of an unstiffened seated connection of a beam to the flange of a column from the following data: Rolled steel column = ISHB 300 @ 576.8 N/m; Rolled steel beam = ISMB 225 @ 306.1 N/m; Seat angle = ISA 100 mm x 75 mm x 8 mm; Top cleat angle = ISA 90 mm x 90 mm x 8 mm; Diameter of rivets = 20 mm.
-
May 2015 Draw to a suitable scale the front and side elevations of seated beam to beam connection using the following data: Main beam = ISMB 500 @ 852.5 N/m; Secondary beam = ISMB 250 @ 365.9 N/m; Seat angle = ISA 100 mm x 90 mm x 10 mm; Top cleat angle = ISA 80 mm x 80 mm x 10 mm; Nominal diameter of rivet = 20 mm.
-
May 2015 Draw to a suitable scale the front and side elevation of an unstiffened seated connection of a beam to the flange of a column from the following data: Rolled steel column = ISHB 300 @ 576.8 N/m; Rolled steel beam = ISMB 225 @ 306.1 N/m; Seat angle = ISA 100 mm x 75 mm x 8 mm; Top cleat angle = ISA 90 mm x 90 mm x 8 mm; Diameter of rivets = 20 mm.
-
May 2015 Draw to a suitable scale the front and side elevations of seated beam to beam connection using the following data: Main beam = ISMB 500 @ 852.5 N/m; Secondary beam = ISMB 250 @ 365.9 N/m; Seat angle = ISA 100 mm x 90 mm x 10 mm; Top cleat angle = ISA 80 mm x 80 mm x 10 mm; Nominal diameter of rivet = 20 mm.
-
Dec 2015 Draw the front elevation and side elevation of seated beam-to-beam connection from the given data: main beam ISMB 350 @ 853.6 N/mm2; secondary beam ISLB 300 @ 369.8 N/mm2; seat angle 150 × 150 × 10 mm @ 223.7 N/m2; web cleat angle 75 × 75 × 8 mm; diameter of rivets 16 mm.
-
Dec 2015 Draw to a suitable scale the front and side elevations of an unstiffened seated connection of a beam with web of a column from the following data: column ISHB 350 @ 661.2 N/m; beam ISMB 225 @ 306.1 N/m; seat angle ISA 100 × 75 × 10 mm; top cleat angle ISA 90 × 90 × 10 mm; nominal diameter of rivets 20 mm.
-
Dec 2015 Draw the front elevation and side elevation of seated beam to beam connection from the data given as under: Main = ISMB 350 @ 853.6N/mm2; Secondary Beam = ISLB 300 @ 369.8N/mm2; Seat angle = 150×150×10mm @ 223.7N/m2; Web cleat angle = 75×75×8mm; Diameter of rivets = 16mm.
-
Dec 2015 Draw to a suitable scale the front and side elevations of an unstiffened seated connection of a beam with web of a column from the following data: Column = ISHB 350 @ 661.2N/m; Beam = ISMB 225 @ 306.1N/m; Seat angle = ISA 100×75×10mm; Top cleat angle = ISA 90×90×10mm; Nominal diameter of rivets = 20mm.
-
-
Draw the section of plate girder with intermediate joggled vertical stiffners from the following data: Web plate = 1000mm x 8mm; Flange angle = 2-ISA 150mm x 115mm x 8mm (2 at top 2 at bottom); Flange cover plates = 400mm x 10 mm (one at top one at bottom); Joggled vertical stiffner = 2-ISA 100mm x 75mm x 8mm.Long Answer 25 Marks May-2020 • PSBTE DIPLOMA
-
Dec 2018 Draw the section of plate girder with intermediate joggled vertical stiffeners from the following data: web plate = 1000 mm x 10 mm, flange angle = 2-ISA 150 mm x 115 mm x 8 mm (2 at top, 2 at bottom), flange cover plates = 400 mm x 10 mm (one at top, one at bottom), joggled vertical stiffener = 2-ISA 100 mm x 75 mm x 8 mm.
-
Dec 2016 Draw the section of plate girder with intermediate joggled vertical stiffeners from the following data: web plate = 1000 mm x 8 mm; flange angle = 2-ISA 150 mm x 115 mm x 8 mm (2 at top, 2 at bottom); flange cover plates = 400 mm x 10 mm (one at top, one at bottom); joggled vertical stiffener = 2-ISA 100 mm x 75 mm x 8 mm.
-
Explore all data
FAQ
Frequently Asked Questions
Answers about this subject, solved papers, and preparation.
01 Where can I find Structural Drawing previous year papers for Civil 6th semester?
This page is meant to help students find subject-wise previous year papers and old question papers for Structural Drawing in Civil Engineering 6th semester.
02 Can I download Structural Drawing question paper PDF here?
The page is designed for finding question paper material and related PDFs where available, so students can revise from old papers.
03 How do Structural Drawing old papers help in exam preparation?
They help you understand the question style, paper pattern, and commonly repeated areas, which makes revision easier before exams.
04 Are these official question papers from PSBTE?
No. BRpaper is not the official website of Punjab State Board of Technical Education. It only helps students discover previous year paper resources.
05 Are solved papers available for Structural Drawing?
Where available, students may use solved papers or answer content for practice, but this page does not claim to provide every solved paper.